Klippon WDU 2.5N ZQV Terminal

Klippon WDU 2.5N ZQV Terminal

£1.03 Incl. VAT

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 32A, 48 V DC coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3, AC-4 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 32 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 15 kW at 380…400 V AC 50/60 Hz AC-3, 15 kW at 415…440 V AC 50/60 Hz AC-3, 18.5 kW at 500 V AC 50/60 Hz AC-3, 18.5 kW at 660…690 V AC 50/60 Hz AC-3, 7.5 kW at 220…230 V AC 50/60 Hz AC-3, 7.5 kW at 400 V AC 50/60 Hz AC-4 – motor power hp: 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 50 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 138 A <= 40 °C 1 min power circuit, 140 A 100 ms signalling circuit, 260 A <= 40 °C 10 s power circuit, 430 A <= 40 °C 1 s power circuit, 60 A <= 40 °C 10 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 1.4 Mcycles 50 A AC-1 at Ue <= 440 V, 1.65 Mcycles 32 A AC-3 at Ue <= 440 V – power dissipation per pole: 2 W AC-3, 5 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, power circuit : screw clamp terminals 1 cable(s) 1…10 mm² – cable stiffness: flexible – with cable end, power circuit : screw clamp terminals 1 cable(s) 1.5…10 mm² – cable stiffness: solid – without cable end, power circuit : screw clamp terminals 1 cable(s) 2.5…10 mm² – cable stiffness: flexible – without cable end, power circuit : screw clamp terminals 2 cable(s) 1.5…6 mm² – cable stiffness: flexible – with cable end, power circuit : screw clamp terminals 2 cable(s) 2.5…10 mm² – cable stiffness: flexible – without cable end, power circuit : screw clamp te

100 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 1040800000 Categories: , , Brand: Part Number: 2500196472

Description

Technical Specifications  Technical Specifications Feed-through terminal block Connection position Inclined Inflammability class of insulation material acc. with UL94 V0 Colour Beige Mounting method Direct mounting Material insulation body Thermoplastic Height at lowest possible mounting height 37 mm Number of levels 1 Width/grid dimension 5.1 mm Rated current In 24 A Rated voltage 500 V Length 44 mm Type of electrical connection 2 Screw connection Type of electrical connection 1 Screw connection Number of clamp positions per level 2 Operating temperature -50 – 120 °C Connectable conductor cross section fine-strand with cable end sleeve 0.5 – 2.5 mm² Connectable conductor cross section fine-strand without cable end sleeve 0.5 – 4 mm² Connectable conductor cross section solid-core 0.5 – 4 mm² Connectable conductor cross section multi-wired 1.5 – 4 mm² Explosion-tested version ‘Ex e’ No Closing plate required Yes Internally connected stages No · Technical Data Sheet – Click to Download