Lewden Split Load Consumer Units
£203.63 Incl. VAT
RCCBs are part of our Dual RCCB solutions offer, which are a range of High Integrity Consumer Units, providing individual circuits arranged across two RCCBs, with the additional capability to provide Residual current protection to designated circuits via RCBOs connected directly to the Main Switch · · · 100A Incoming Switch · · 2 x 80A Type A 30mA RCDs · · Designed with the Installer in mind, providing an easy to install consumer unit, meeting the requirements of the latest 18th Edition Wiring Regulations in a stylish, non-obtrusive range of Enclosures.
✓ In stock – Delivery in 1–2 days
Description
Technical Specifications Technical Specifications Small distribution board equipped Width 353 mm Height 266 mm Number of poles main switch – Width in number of modular spacings – Number of groups behind earth leakage switch – Number of light groups – Number of earth leakage switches 30 mA – Number of direct groups – Number of phases 1 Number of earth leakage switches 300 mA – Main switch rated current 100 A Depth 106 mm Number of arc fault detection devices AFDD – Number of earth leakage circuit breakers – Total number of groups – Number of outgoing ways 10 Built-in depth – mm With socket outlet No Lockable No Extension possible No Over voltage-/surge protection No With metering No With transparent cover No Suitable for data No Protection dual RCD No Protection incoming RCD Yes With bell transformer No Protection high integrity No Cooker group suitable as power current group No Protection main switch Yes Protection split load No · Technical Data Sheet – Click to Download · Technical Data Sheet – Click to Download