Merlin Gerin ICT 16A 2NO 2NC 220-240V 50Hz Contactor
£136.13 Incl. VAT
This Acti9 iCT is a modular contactor. It is a 4P remote control device with 2 normally open contacts and 2 normally close contacts. The In rated current is 16A for AC-7a and 6A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 81mm x (H) 36mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C. · · · Control and monitoring of electrical circuits in all industrial, commercial and residential buildings. · · Control and monitoring of single- or three-phase loads up to 100A. · · Interface between the control gear & power circuits for final circuits such as lighting, heating, roller blind, watering system, ovens, utility motors: ventilation, heat pump etc. · · Peace of mind with the complete modular system · · Flexible auxiliaries combination with a simple clip-on system · · Consistent with the entire Acti 9 offer · · Compliance with standards: EN 61095 and CEI 1095 · · Rated voltage conducter-earth: 230V · · Rated voltage conducter-conductor: 400V · · Rated impulse voltage: 4kV
Out of stock
Description
Technical Specifications Technical Specifications Contactor for distribution board installation Number of contacts as normally closed contact 2 Number of contacts as normally open contact 2 Max. load fluorescent lamp (Duo circuit) 4500 VA Max. incandescent lamp load 6000 W Max. load fluorescent lamp 2550 VA Rated operation current 16 A Number of modular spacings 2 Max. load fluorescent lamp (parallel compensated) 2400 VA Utility category 7 Recess depth 43.5 mm Rated operating voltage 400 – 400 V Rated excitation voltage 220 – 240 V Slider for hand switch No Additional equipment possible Yes · Technical Data Sheet – Click to Download






