RCD Vigi Ic60 Add-On Four Pole Type A 63A 300Ma
£240.98 Incl. VAT
This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 3P + N, rated current is 63A, operating voltage is 415VAC according to IEC 61009-1. The earth leakage protection class is A type with a sensitivity of 300mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with Acti9 iC60 circuit breaker to provide protection of persons and protection of installations. This product is compliant with EN 61009-1 and IEC 61009-1 standard. The Ue rated operational voltage is 400VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 6. The dimensions are (W) 108mm x (H) 91mm x (D) 73.5mm. The weight is 0.245kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature -5°C to +60°C. The storage temperature is -40°C to +85°C. · · · The absolute safety for earth leakage protection in final distribution · · Greater continuity of service with VisiTrip · · Greater electrical immunity with Si type (Super immune), · · Easy to install with robust terminal connections · · Environmentally friendly with 100% recyclable & recoverable materials · · Compliance with standard IEC EN 61009-1, certified by national official authorities · · This product is compliant with EN 61009-1 and IEC 61009-1 standard. · · The Ue rated operational voltage is 400VAC. · · The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV.
2 available – delivery in 1–2 days
Description
Technical Specifications Technical Specifications Residual current circuit breaker (RCCB) module Nominal current 63 A Number of poles 4 Rated insulation voltage Ui 500 V Max. delay time 0 ms Pollution degree 3 Surge current capacity 0.25 kA Rated impulse-withstand voltage (Uimp) 6 kV Nominal voltage 400 – 415 V Rated fault current 0.3 – 0.3 A Connectable conductor cross section solid-core 1 – 35 mm² Ambient temperature during operating 5 – 60 °C Connectable conductor cross section multi-wired 1 – 25 mm² Anti-nuisance tripping version No With interlocking device No Delay adjustable No Rated fault current adjustable No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2190549