Schneider Electric Power Base Tesys U 12A 24V AC Screw Clamps Control

Schneider Electric Power Base Tesys U 12A 24V AC Screw Clamps Control

£196.76 Incl. VAT

TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a -all in one- reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0B to be supplied with 24V AC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). · · · TeSys U standard reversing power base, 3 poles (3NO), rated 12A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 5.5kW@400V. · · Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a “all in one” reversing starter controller with basic or advanced protection and control functions. · · It is equipped with a reverser module LU2MB0B to be supplied with 24V AC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. · · It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. · · Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. · · Depth: 126mm · · Normal State Configuration: 2 No

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: LU2B12B Brand: Product Code: 2500246313

Description

Technical Specifications  Technical Specifications Motor starter/Motor starter combination Depth 126 mm Width 45 mm Height 224 mm Number of command positions 3 Rated operation power at AC-3, 400 V 5.5 kW Number of auxiliary contacts as normally open contact 1 Rated operation power at AC-3, 230 V, 3-phase 3 kW Rated conditional short-circuit current, type 1, 480 Y/277 V 10000 A Rated power, 460 V, 60 Hz, 3-phase 5.5 kW Rated power, 575 V, 60 Hz, 3-phase 5.5 kW Rated conditional short-circuit current, type 1, 600 Y/347 V 4000 A Number of auxiliary contacts as normally closed contact 1 Number of indicator lights 0 Rated operation current at AC-3, 400 V 12 A Rated conditional short-circuit current, type 2, 230 V 50000 A Rated conditional short-circuit current, type 2, 400 V 50000 A Ambient temperature, upper operating limit 70 °C Rated operation current Ie 12 A Rated control supply voltage at AC 50 Hz 24 – 24 V Rated control supply voltage at AC 60 Hz 24 – 24 V Overload release current setting – – – A Rated control supply voltage at DC – – – V With transformer No Supporting protocol for PROFIBUS No Supporting protocol for TCP/IP No Supporting protocol for CAN No Rail mounting possible Yes Supporting protocol for other bus systems No Supporting protocol for SERCOS No Supporting protocol for INTERBUS-Safety No Supporting protocol for PROFINET IO No Supporting protocol for PROFINET CBA No Supporting protocol for Foundation Fieldbus No Supporting protocol for INTERBUS No Supporting protocol for ASI No Supporting protocol for MODBUS No Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No Supporting protocol for SUCONET No Supporting protocol for LON No External reset possible No With short-circuit release Yes Temperature compensated overload protection No With fuse No Supporting protocol for SafetyBUS p No Supporting protocol for DeviceNet Safety No Supporting protocol for PROFIsafe No Suitable for emergency stop No Supporting protocol for AS-Interface Safety at Work No Supporting protocol for EtherNet/IP No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2188172 · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2188241