Schneider Electric Safety Module For Tm2Xx 1
£357.13 Incl. VAT
SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS. range of product: Modicon TM3 Safety – product or component type: safety module – device short name: TM3SAF – safety module application: for emergency stop and switch monitoring – function of module: emergency stop monitoring 1-channel wiring, emergency stop monitoring 2-channel wiring, monitoring of a movable guard with 2 switches and automatic start – safety level: can reach PL e/category 4 EN/ISO 13849-1:2008, can reach PL e/category 4 EN/ISO 13849-2:2012, can reach SIL 3 EN/IEC 61508:2010, can reach SILCL 3 EN/IEC 62061:2005. · · · This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches. · · It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. · · It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. · · It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. · · It has removable terminals for easier and better control wires tightening, thus improving installation reliability.
Out of Stock
Description
Technical Specifications Technical Specifications Device for monitoring of safety-related circuits Height – mm Width – mm Depth – mm Number of outputs, safety related, undelayed, with contact – Number of outputs, safety related, delayed, with contact – Number of outputs, safety related, undelayed, semiconductors – Number of outputs, safety related, delayed, semiconductors – Number of outputs, signalling function, delayed, with contact – Number of outputs, signalling function, undelayed, with contact – Number of outputs, signalling function, undelayed, semiconductors – Number of outputs, signalling function, delayed, semiconductors – Release-delay – – – s With approval according to UL No With approval for BG BIA No With muting function No Suitable for monitoring of position switches No Suitable for monitoring of emergency-stop circuits No Suitable for monitoring of valves No Suitable for monitoring of optoelectronic protection equipment No Suitable for monitoring of tactile sensors No Suitable for monitoring of magnetic switches No Suitable for monitoring of proximity switches No With feedback circuit No With start input No With detachable clamps No Rail mounting possible No · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2192648