Schneider Electric TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 18A, 110 V AC coil

Schneider Electric TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 18A, 110 V AC coil

£68.26 Incl. VAT

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 18A, 110 V AC coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3, AC-4 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 18 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 32 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 10 kW at 500 V AC 50/60 Hz AC-3, 10 kW at 660…690 V AC 50/60 Hz AC-3, 4 kW at 220…230 V AC 50/60 Hz AC-3, 4 kW at 400 V AC 50/60 Hz AC-4, 7.5 kW at 380…400 V AC 50/60 Hz AC-3, 9 kW at 415…440 V AC 50/60 Hz AC-3 – motor power hp: 1 hp at 115 V AC 50/60 Hz for 1 phase motors, 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 32 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 145 A <= 40 °C 10 s power circuit, 240 A <= 40 °C 1 s power circuit, 40 A <= 40 °C 10 min power circuit, 84 A <= 40 °C 1 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 35 A gG at <= 690 V coordination type 2 for power circuit, 50 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 1 Mcycles 32 A AC-1 at Ue <= 440 V, 1.65 Mcycles 18 A AC-3 at Ue <= 440 V – power dissipation per pole: 0.8 W AC-3, 2.5 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : lugs-ring terminals – external diameter: 8 mm, power circuit : lugs-ring terminals – external diameter: 8 mm – tightening torque: control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5, power circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 8 mm screw : M3.5, power circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5 – operating time: 12…22 ms closing, 4…19 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 15 Mcycles. · · · TeSys D contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3 (7.5kW@400V). · · It provides a 110V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. · · For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. · ·

Out of Stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: LC1D186F7 Categories: , , Brand: Product Code: 2500876472

Description

Technical Specifications  Technical Specifications Power contactor, AC switching Rated operation power NEMA – kW Rated operation power at AC-3, 400 V 7.50 kW Number of auxiliary contacts as normally closed contact 1.00 Rated operation power at AC-4, 400 V 4.00 kW Rated operation current Ie at AC-1, 400 V 32.00 A Rated operation current Ie at AC-4, 400 V 9.00 A Rated operation current Ie at AC-3, 400 V 18.00 A Number of main contacts as normally open contact 3.00 Number of auxiliary contacts as normally open contact 1.00 Number of normally closed contacts as main contact 0.00 Rated control supply voltage at AC 50 Hz 110.00 – 110.00 V Rated control supply voltage at AC 60 Hz 110.00 – 110.00 V Rated control supply voltage at DC – – – V Modular version No · Technical Data Sheet – Click to Download