Schneider Electric TeSys SK mini contactor, 2p (2 NO), AC-3, 690 V 6A, 110 V AC coil
£31.28 Incl. VAT
TeSys SK mini contactor, 2p (2 NO), AC-3, 690 V 6A, 110 V AC coil. range: TeSys – product name: TeSys SK – product or component type: mini contactor – device short name: LC1SK – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3 – poles description: 2P – pole contact composition: 2 NO – [Ie] rated operational current: 12 A (<= 55 °C) AC AC-1, 6 A at <= 440 V AC AC-3 – motor power kW: 1.1 kW at 220…230 V AC 50/60 Hz, 2.2 kW at 380…415 V AC 50/60 Hz, 2.2 kW at 660…690 V AC 50/60 Hz – Irms rated making capacity: 66 A at 690 V AC conforming to IEC 60947, 66 A at 690 V AC conforming to NF C 63-110 – rated breaking capacity: 52 A at <= 400 V for power circuit conforming to IEC 60947, 52 A at <= 400 V for power circuit conforming to NF C 63-110 – [Ui] rated insulation voltage: 690 V conforming to BS 5424, 690 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947, 690 V conforming to UL 508, 690 V conforming to VDE 0110 group C – mounting support: rail – standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660 – product certifications: cULus – connections – terminals: power circuit : connector 1 cable(s) 0.35…6 mm² – cable stiffness: flexible – with cable end, power circuit : connector 1 cable(s) 0.5…6 mm² – cable stiffness: flexible – without cable end, power circuit : connector 1 cable(s) 1.5…6 mm² – cable stiffness: solid, power circuit : connector 2 cable(s) 0.35…1.5 mm² – cable stiffness: flexible – with cable end, power circuit : connector 2 cable(s) 0.35…2.5 mm² – cable stiffness: flexible – without cable end, power circuit : connector 2 cable(s) 1.5…4 mm² – cable stiffness: solid – operating time: 6…8 ms coil de-energisation and NO opening, 7…14 ms coil energisation and NO closing – mechanical durability: 10 Mcycles. · · · TeSys SK mini-contactor, 2 poles (2NO), for non inductive load applications up to 12A/690V AC-1, · · and for 1-phase motor control applications up to 6A/690V AC-3 (for 3-phase motors an add-on contact block LA1SK must be mounted on contactor). · · It provides a 110V 50/60Hz AC control circuit, connection by screw clamp terminals. · · For operating rates until 1200 cycles/hour and ambient temperature -20/+50°C, it procures high reliability and durability. · · Compact (27mm width), for clipping on a 35mm DIN rail.
Out of Stock
Description
Technical Specifications Technical Specifications Power contactor, AC switching Number of normally closed contacts as main contact 0.00 Number of main contacts as normally open contact 2.00 Rated operation power at AC-3, 400 V 2.20 kW Number of auxiliary contacts as normally open contact 0.00 Rated operation power NEMA – kW Rated operation current Ie at AC-4, 400 V – A Rated operation power at AC-4, 400 V – kW Rated operation current Ie at AC-3, 400 V 6.00 A Rated operation current Ie at AC-1, 400 V 12.00 A Number of auxiliary contacts as normally closed contact 0.00 Rated control supply voltage at AC 50 Hz 110.00 – 110.00 V Rated control supply voltage at AC 60 Hz 110.00 – 110.00 V Rated control supply voltage at DC – – – V Modular version No · Technical Data Sheet – Click to Download