Siemens Circuit Breaker 3Va1 Iec Frame 160 Breaki

Siemens Circuit Breaker 3Va1 Iec Frame 160 Breaki

£444.70 Incl. VAT

circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A fixed short-circuit protection Ii=10 x In clamp connection 3VA1 molded-case circuit breaker for starter protection. As an important element of SENTRON protective components for industrial and infrastructure applications, the 3VA molded-case circuit breakers from Siemens provide effective plant, starter and motor protection thanks to reliable shutdown in the event of an overload or short circuit. The 3VA molded-case circuit breakers set new standards in flexibility and the variety of modular accessories available. Standardized accessories for several sizes across all series of the 3VA1 and 3VA2 molded-case circuit breakers. Key features of this version of the 3VA molded-case circuit breaker: 1. Compact design. 2. Available as version for starter circuit breaker to protect electrical motors from short circuits. 3. Available as 3-pole version. 4. Depending on the size: Rated operating current of 32áA to 200áA. 5. Breaking capacity of 55ákA to 70ákA at 415áV. 6. Fixed and plug-in installation possible. 7. The series has a thermo-magnetic trip unit 8. Modular and easy-to-fit internal accessories with wide range of functions. 9. Integrated accessories platform for all 3VA molded-case circuit breakers. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry. · · · MCCB_IEC_FS160_160A_3P_25KA_TM_ FTFM

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 3VA1116-3ED36-0AA0 Categories: , , Brand: Product Code: 2501253821

Description

Technical Specifications  Technical Specifications Moulded case circuit breaker (MCCB) Number of auxiliary contacts as normally open contact 0 Number of poles 3 Number of auxiliary contacts as change-over contact 0 Number of auxiliary contacts as normally closed contact 0 Rated short-circuit breaking capacity Icu at 400 V, 50 Hz 25 kA Rated permanent current Iu 160 A Motor drive integrated No Rated voltage 220 – 690 V Integrated earth fault protection No With integrated under voltage release No Switched-off indicator available Yes DIN rail (top hat rail) mounting optional Yes Motor drive optional Yes Complete device with protection unit Yes Suitable for DIN rail (top hat rail) mounting No