Siemens Circuit Breaker 3VA1 IEC Frame 160 Breaking Capacity Class S Icu=36kA @ 415V 3-Pole, Line Protection TM220, ATFM, In=63A Overload Protection Ir=44A…
£289.84 Incl. VAT
circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM220, ATFM, In=63A overload protection Ir=44A…63A short-circuit protection Ii=10 x In clamp connection 3VA1 molded-case circuit breaker for starter protection. As an important element of SENTRON protective components for industrial and infrastructure applications, the 3VA molded-case circuit breakers from Siemens provide effective plant, starter and motor protection thanks to reliable shutdown in the event of an overload or short circuit. The 3VA molded-case circuit breakers set new standards in flexibility and the variety of modular accessories available. Standardized accessories for several sizes across all series of the 3VA1 and 3VA2 molded-case circuit breakers. Key features of this version of the 3VA molded-case circuit breaker: 1. Compact design. 2. Available as version for starter circuit breaker to protect electrical motors from short circuits. 3. Available as 3-pole version. 4. Depending on the size: Rated operating current of 32 A to 200 A. 5. Breaking capacity of 55 kA to 70 kA at 415 V. 6. Fixed and plug-in installation possible. 7. The series has a thermo-magnetic trip unit 8. Modular and easy-to-fit internal accessories with wide range of functions. 9. Integrated accessories platform for all 3VA molded-case circuit breakers. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
✓ In stock – Delivery in 1–2 days
Description
Technical Specifications Technical Specifications Moulded case circuit breaker (MCCB) Rated permanent current Iu 63 A Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Number of auxiliary contacts as normally closed contact 0 Rated short-circuit breaking capacity Icu at 400 V, 50 Hz 36 kA Number of poles 3 Rated voltage 220 – 690 V Overload release current setting 44 – 63 A Integrated earth fault protection No With integrated under voltage release No Suitable for DIN rail (top hat rail) mounting No Motor drive integrated No Complete device with protection unit Yes DIN rail (top hat rail) mounting optional Yes Switched-off indicator available Yes Motor drive optional Yes · Technical Data Sheet – Click to Download