circuit breaker 3VA1 IEC frame 250 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=250A overload protection Ir=175A…250A short-circuit protection Ii=5…10 x In nut keeper kit 3VA1 molded-case circuit breaker for starter protection. As an important element of SENTRON protective components for industrial and infrastructure applications, the 3VA molded-case circuit breakers from Siemens provide effective plant, starter and motor protection thanks to reliable shutdown in the event of an overload or short circuit. The 3VA molded-case circuit breakers set new standards in flexibility and the variety of modular accessories available. Standardized accessories for several sizes across all series of the 3VA1 and 3VA2 molded-case circuit breakers. Key features of this version of the 3VA molded-case circuit breaker: 1. Compact design. 2. Available as version for starter circuit breaker to protect electrical motors from short circuits. 3. Available as 3-pole version. 4. Depending on the size: Rated operating current of 32áA to 200áA. 5. Breaking capacity of 55ákA to 70ákA at 415áV. 6. Fixed and plug-in installation possible. 7. The series has a thermo-magnetic trip unit 8. Modular and easy-to-fit internal accessories with wide range of functions. 9. Integrated accessories platform for all 3VA molded-case circuit breakers. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry. · · · MCCB_IEC_FS250_250A_3P_36KA_TM_ ATAM
✓ In stock – Delivery in 1–2 days
Description
Technical Specifications Technical Specifications Moulded case circuit breaker (MCCB) Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Rated permanent current Iu 250 A Rated short-circuit breaking capacity Icu at 400 V, 50 Hz 36 kA Number of poles 3 Number of auxiliary contacts as change-over contact 0 Overload release current setting 175 – 250 A Adjustment range undelayed short-circuit release 1250 – 2500 A Rated voltage 220 – 690 V With integrated under voltage release No Motor drive optional Yes DIN rail (top hat rail) mounting optional No Integrated earth fault protection No Complete device with protection unit Yes Motor drive integrated No Switched-off indicator available Yes Suitable for DIN rail (top hat rail) mounting No · Technical Data Sheet – Click to Download