Miniature circuit breaker 240 V 14kA, 1-pole, B, 10A, D=70 mm according to UL 489, equal polarity The miniature circuit breaker is the fuse for short-circuit protection. The miniature circuit breakers from Siemens, as an important component of the SENTRON protective components for electronic installations, provide effective protection for personnel and plants by reliably shutting down in the event of an overload or short-circuit. User-friendly mounting and connection technology, standardized additional components and an integrated design – these are the characteristics of the device family. Whether for infrastructure or for industrial requirements, Siemens provides miniature circuit breakers for all applications and every application area. The Siemens miniature circuit breakers are characterized primarily by: 1. Effective personnel, investment and plant protection against overload and short-circuits. 2. A wide variety of standardized accessories, easy to install and replaceable at any time. 3. Reliable safety during installation due to standard reach-around and touch protection. 4. Clearly visible switch position indicator. 5. The data matrix code on the front of the device provides quick and easy access to information on all aspects of miniature circuit breakers. 6. Protection as per the standards with worldwide approvals.

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 5SJ4110-6HG40 Brand: Product Code: 1050452460

Description

Technical Specifications  Technical Specifications Miniature circuit breaker (MCB) Tripping characteristic (type/curve) B Degree of protection (IP rating) IP20 Voltage type AC/DC Rated voltage 400 V Recess depth 70 mm Rated current 10 A Number of protected poles – Rated insulation voltage Ui 440 V Number of poles (total) 1 Current limiting class – Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 15 kA Width in number of modular spacings 1 Rated impulse-withstand voltage (Uimp) – kV Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 15 kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 10 kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V 10 kA Over voltage category 3 Pollution degree 3 Frequency 50 – 50 Hz Connectable conductor cross section solid-core – mm² Connectable conductor cross section multi-wired – mm² Ambient temperature during operating -25 – 55 °C Additional equipment possible Yes Concurrently switching N-neutral No