RCBO, 10 kA, 1P+N, type A, 30 mA, B char., In: 16 A, Un AC: 230 V RCBOs for combined short-circuit protection and anti-contact protection. An important element of the SENTRON protective devices for electrical installations, the patented RCBOs from Siemens allow combined personnel, fire and cable protection in just one device. In addition to detecting the fault currents, they also provide reliable protection against short-circuits and overloads thanks to the integrated overcurrent protective device. As a combination of residual current and miniature circuit breaker, the Siemens RCBOs are primarily characterized by: 1. Increased operational safety and system availability due to separate disconnection of the affected circuit. 2. Whether sinusoidal residual alternating currents or smooth residual direct currents, Siemens provides the right type for all requirements and special versions. 3. Reliable safety during installation due to standard reach-around and touch protection. 4. Toolless removal from the standard mounting rail or from the busbar assembly simply by operating a manual slide. 5. Clearly visible switch position indicator. 6. The data matrix code on the front of the device provides quick and easy access to information on all aspects of the RCBOs. 7. Be protected according to the standards: The RCBOs correspond to the provisions of DIN VDE. 8. Optimized technology for your safety – only from Siemens. · · · RCBO elm
Description
Technical Specifications Technical Specifications Earth leakage circuit breaker/RCBO Disconnection characteristic Undelayed Tripping characteristic (type/curve) B Degree of protection (IP rating) IP20 Leakage current type A Voltage type AC Rated current 16 A Rated fault current 0.03 A Rated voltage 230 V Recess depth 70 mm Over voltage category 3 Rated impulse-withstand voltage (Uimp) 4 kV Pollution degree 2 Rated short-circuit breaking capacity according to EN 61009 10 kA Rated short-circuit breaking capacity IEC 60947-2 20 kA Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA Current limiting class 3 Number of poles (total) 2 Surge current capacity 1 kA Number of protected poles 1 Rated insulation voltage Ui 264 V Width in number of modular spacings 2 Connectable conductor cross section solid-core 0.75 – 35.0 mm² Connectable conductor cross section multi-wired 0.75 – 35.0 mm² Concurrently switching N-neutral Yes With interlocking device Yes Anti-nuisance tripping version Yes · Technical Data Sheet – Click to Download