RCBO, 10 kA, 1P+N, type A, 30 mA, B char., In: 32 A, Un AC: 230 V RCBOs for combined short-circuit protection and anti-contact protection. An important element of the SENTRON protective devices for electrical installations, the patented RCBOs from Siemens allow combined personnel, fire and cable protection in just one device. In addition to detecting the fault currents, they also provide reliable protection against short-circuits and overloads thanks to the integrated overcurrent protective device. As a combination of residual current and miniature circuit breaker, the Siemens RCBOs are primarily characterized by: 1. Increased operational safety and system availability due to separate disconnection of the affected circuit. 2. Whether sinusoidal residual alternating currents or smooth residual direct currents, Siemens provides the right type for all requirements and special versions. 3. Reliable safety during installation due to standard reach-around and touch protection. 4. Toolless removal from the standard mounting rail or from the busbar assembly simply by operating a manual slide. 5. Clearly visible switch position indicator. 6. The data matrix code on the front of the device provides quick and easy access to information on all aspects of the RCBOs. 7. Be protected according to the standards: The RCBOs correspond to the provisions of DIN VDE. 8. Optimized technology for your safety – only from Siemens. · · · RCBO elm

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 5SU1354-6KK32 Categories: , , Brand: Product Code: 2500183564

Description

Technical Specifications  Technical Specifications Earth leakage circuit breaker/RCBO Tripping characteristic (type/curve) B Disconnection characteristic Undelayed Degree of protection (IP rating) IP20 Leakage current type A Voltage type AC Rated current 32 A Rated impulse-withstand voltage (Uimp) 4 kV Rated voltage 230 V Rated fault current 0.03 A Recess depth 70 mm Width in number of modular spacings 2 Rated insulation voltage Ui 264 V Number of protected poles 1 Current limiting class 3 Surge current capacity 1 kA Rated short-circuit breaking capacity IEC 60947-2 15 kA Pollution degree 2 Number of poles (total) 2 Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA Over voltage category 3 Rated short-circuit breaking capacity according to EN 61009 10 kA Connectable conductor cross section solid-core 0.75 – 35.0 mm² Connectable conductor cross section multi-wired 0.75 – 35.0 mm² With interlocking device Yes Anti-nuisance tripping version Yes Concurrently switching N-neutral Yes · Technical Data Sheet – Click to Download