Siemens RCBO DP Type A C Characteristic 6A 30Ma 6Ka

Siemens RCBO DP Type A C Characteristic 6A 30Ma 6Ka

£155.75 Incl. VAT

RCBO, 6 kA, 1P+N, type A, 30 mA, C-Char, In: 6 A, Un AC: 230 V RCBOs for combined short-circuit protection and anti-contact protection. An important element of the SENTRON protective devices for electrical installations, the patented RCBOs from Siemens allow combined personnel, fire and cable protection in just one device. In addition to detecting the fault currents, they also provide reliable protection against short-circuits and overloads thanks to the integrated overcurrent protective device. As a combination of residual current and miniature circuit breaker, the Siemens RCBOs are primarily characterized by: 1. Increased operational safety and system availability due to separate disconnection of the affected circuit. 2. Whether sinusoidal residual alternating currents or smooth residual direct currents, Siemens provides the right type for all requirements and special versions. 3. Reliable safety during installation due to standard reach-around and touch protection. 4. Toolless removal from the standard mounting rail or from the busbar assembly simply by operating a manual slide. 5. Clearly visible switch position indicator. 6. The data matrix code on the front of the device provides quick and easy access to information on all aspects of the RCBOs. 7. Be protected according to the standards: The RCBOs correspond to the provisions of DIN VDE. 8. Optimized technology for your safety – only from Siemens. · · · RCBO elm

Typically available in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: 5SU1356-7KK06 Categories: , , Brand: Product Code: 2500184161

Description

Technical Specifications  Technical Specifications Earth leakage circuit breaker/RCBO Tripping characteristic (type/curve) C Disconnection characteristic Undelayed Degree of protection (IP rating) IP20 Voltage type AC Rated impulse-withstand voltage (Uimp) 4 kV Leakage current type A Width in number of modular spacings 2 Rated short-circuit breaking capacity according to EN 61009 6 kA Rated short-circuit breaking capacity Icn according to EN 61009-1 6 kA Over voltage category 3 Current limiting class 3 Number of poles (total) 2 Surge current capacity 1 kA Pollution degree 2 Rated short-circuit breaking capacity IEC 60947-2 25 kA Number of protected poles 1 Rated insulation voltage Ui 264 V Rated current 6 A Rated voltage 230 V Rated fault current 0.03 A Recess depth 70 mm Connectable conductor cross section solid-core 0.75 – 35.0 mm² Connectable conductor cross section multi-wired 0.75 – 35.0 mm² With interlocking device Yes Concurrently switching N-neutral Yes Anti-nuisance tripping version Yes · Technical Data Sheet – Click to Download