Twinflexpro2 Starter Kit (Inc. 4 Zone Panel, 7X Asd Detectors, 2X Fdw100 Mcp’S, 1X Fdw500)
£873.53 Incl. VAT✓ In Stock for Delivery
This kit is based upon the popular Fike Twinflex Pro range of two wire fire alarm system equipment. This means that the detectors, call points and sounders can all be installed on the same zone circuit. This reduces installation costs, time and disruption compared to traditional conventional fire alarm systems, where the sounders would need to be installed separately to the detectors and call points.This kit includes the Twinflex Multipoint detectors which can be used as either a smoke or heat detector. This is selectable by simply adjusting the switches on the reverse of the detector. This means that separate smoke and heat detectors don’t need to be ordered. · · · Four zone panel · · Up to 32 devices per zone · · Four line LCD display · · Three enhanced test modes · · Construction V0 rated ABS · · IP Rating IP 30
-

Fike 505-0008 TwinflexPro – Two Wire 8 Zone Fire Detection Panel & PSU
£542.08 Incl. VAT✓ In Stock for Delivery
This versatile fire alarm panel incorporates Fike’s Multipoint detection system using smoke and heat detectors with built-in sounders, allowing the whole system to be installed using two fire cables. (Requires 140 Battery Pack) · · · All devices have built-in end-of-line monitoring devices · · 7 modes of detection · · Checkpoint alarm verification procedure · · Up to 32 devices per zone · · 8 zone panel is controlled by a key switch · · Allows detectors and sounders to be installed on the same pair of wires · · Walk Test facility · · 72 hour standby
-

Fike 204-0001 2-Wire Detector/Sounder with Base White
£63.96 Incl. VAT✓ In Stock for Delivery
There are 7 modes are available on the detectors and the available modes of detection are smoke heat or a combination of smoke and heat. The mode of detection required can be simply set by configuring the DIL switch in the detector electronic module. · · · Rate of rise mode of detection is to 58°C · · Low fixed temperature mode of detection is 58°C · · High fixed temperature mode of detection is 90°C · · Self calibrates every six hours · · Voltage Range: 24V to 42V DC · · Sounder Volume: Low: 65dB(A)+
-

-

Fike 402-0006 Twinflex Manual Call Point
£38.29 Incl. VAT✓ In Stock for Delivery
Manual callpoint suitable for Fike Twinflex fire alarm systems · · · Units come with a resettable element · · Reset using the key provided · · Can be tested using the test key or by depressing the element · · Can be connected to the back-box using simple flying-lead terminations · · Audible warning with an optional full specification built-in sounder · · 7 different sound patterns · · Supplied with an adaptor plate · · For use with standard flush or surface back boxes
-

Fike 505-0004 4-Zone Conventional Fire Panel
£408.98 Incl. VAT✓ In Stock for Delivery
Biwire 4 Zone panel (excluding batteries) · · · Two-wire installation · · Call point identification · · Built-in end-of-line all devices · · 7 modes of detection · · Complies to BS5839 & EN54 · · Up to 32 devices per zone · · Easy to install · · Up to 72 hour standby capacity · · Warning of head contamination (before going into false alarm)
-

Fike 505-0002 2-Zone Conventional Fire Panel
£353.94 Incl. VATOut of Stock
Biwire 2 Zone panel (excluding batteries) · · · Two-wire installation · · Call point identification · · Built-in end-of-line – No resistors or extra circuits are required · · 7 modes of detection · · Complies to BS5839 & EN54 · · Up to 32 devices per zone · · Easy to install · · Up to 72 hours standby capacity · · Warning of head contamination (before going into false alarm)
-

Twinflex Input/Output Module
£90.72 Incl. VAT✓ In Stock for Delivery
The Twinflex input output module is a Relay interfacing module with monitored input to provide shutdown and monitoring facilities from the Twinflex zone. Mounted in a standard double gang box, including two sets of 2A rated SPCO relay contacts, one monitored input and inbuilt ‘End of Line’. · · · Relay interfacing module with monitored input to provide shutdown and monitoring facilities from the Twinflex zone. · · Mounted in a standard double gang box · · Including two sets of 2A rated SPCO relay contacts · · One monitored input and inbuilt ‘End of Line’ · · Input/Output module · · Mounted on a double gang back-box
-

Twinflex Pro Repeater Panel (Only Available For Use With 4 & 8 Zone Panels Using 2.0 Software)
£310.98 Incl. VAT✓ In Stock for Delivery
The Fike TwinflexPro Repeater Panel is connected directly to the Twinflex Pro² 4 or 8 zone fire alarm panel, and provides remote indication of events which occur on the fire alarm panel. It can also perform system controls over the network (i.e. Silence Alarms, Reset, Sound Alarms & Silence Buzzer). · · · Maximum of 8 repeater panels can be connected to a single control panel · · Reports Twinflex Pro panel events to a remote location · · Capable of performing system controls (i.e. Silence Alarms, Reset, Sound Alarms & Silence Buzzer) · · Maximum of 8 repeater panels can be connected to a single control panel · · Compatible with all Twinflex Pro2 control panels · · All external connections are made on the back board.
-

Twinflex Smoke and Heat Sensor with Base and Sounder 204-0001
£55.60 Incl. VATOut of Stock
Fike Twinflex Smoke and Heat Sensor complete with base and sounder. · · · Switchable between 7 modes of detection · · Includes a sounder · · Supplied complete with base · · End of Line set by Dil Switch · · Supplied with dust cover · · 2 wire connection (no extra wires for sounder) · · Supplied with dust cover
-

Keys for Twinflex Manual Call Point (Pack of 5)
£7.04 Incl. VAT✓ In Stock for Delivery
Keys for use with the Twinflex Manual Call Point. · · · 5 Keys · · Suitable for FDW100 · · same reset key fits all Fike Twinflex manual call points · · Light weight · · Fits on keyring · · Readily available