Your cart is currently empty!
Showing 28–36 of 43 resultsSorted by latest
-
Apollo Sounder Open Area Red for XP95
£56.18 Incl. VATThe Apollo Sonos is an open-area sounder that has been designed for use in open areas and can be connected to any Discovery or XP95 system. A nominal sound output of 100dB(A) is achieved at a current consumption of 5mA in the case of the sounder and 8mA f- 2 volume settings: 92dB(A) & 100dB(A)- IP65 protection rating- Built-in Isolator- Synchronisation of tones- Individual and group addressing- Built-in isolator- Loop-powered- IP65 protection rating
-
Hochiki Mounting Box 32Mm Deep Surface Mounting Box
£1.86 Incl. VATHochiki Surface Mounting Back Box is suitable for HCP-E(SCI) manual call point. It is available in red.- Suitable for HCP-E(SCI) manual call point- For use with HCP-E call point range- Allows addressable call point to be surface mounted- 32 mm deep- Durable- The unit is colour-matched red foruse with the HCP-E range
-
Apollo XP95 Series Detectors Multisensor
£38.95 Incl. VATApollo XP95 Multisensor Detector with optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. Sensitive to a wide range of fires and well-suited to environments such as hotel bedrooms. Unaffected by wind or atmospheric pressure.- Reliable fire detection in areas with a wide temperature range from -20C to 60C- Well suited to environments such as hotel bedrooms, warehouses and loading docks- Unaffected by wind and atmospheric pressure- Alternative to Ionisation detectors- Detection principle Photo-electric light scattering.- Protocol voltage 5 to 9V peak to peak
-
Eaton SFX5G Replacement Glass For Call Point
£14.96 Incl. VATBreakglass replacement- Protective film prevents glass shattering- Spare break glasses for use with callpoints
-
Apollo Detector Smoke Optical Indicator Series 65
£18.90 Incl. VATThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel plated stainless steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode (LED) and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light, modulated at 4kHz. In clear air, light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber, a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a preset threshold, the LED emits two more bursts of light, this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on, increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator, the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition, it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second- Can be used on security systems- Electrically and mechanically compatible with Series 60- Proven detection performance- Responds well to slow-burning, smouldering fires- Status Indicator – Alarm Red- Battery Powered No- Flashing LED and magnet operated test switch option- Wide-operating and storage temperature of -20C to 60C- Applications B&Bs/guest houses Bedrooms Cafes Restaurants Retail Small to medium buildings- IP Rating Value IP23D
-
Apollo Sounder Base For Discovery/XP95 Isolator
£15.25 Incl. VATApollo Discovery Isolating Base senses and detects short-circuit faults on Discovery loops and spurs. Made from self-extinguishing polycarbonate moulding with nickel-plated steel terminals for connecting a detector. The associated detector can be locked into the base using the normal locking screw. it is intended for use with equipment using the Apollo XP95 and Discovery communication protocol. it can hold up to 20 detectors or their equivalent load, may be installed between isolating bases.- Up to 20 detectors or their equivalent load, may be installed between isolating bases- High brightness LED- Detects wiring short-circuits- Minimises disruption from short circuits- White Colour- Polycarbonate housing
-
Resettable Call Point
£12.52 Incl. VATDefinity resettable conventional manual call point.- Surface or flush mounting- Complete with surface back box- Spare cover available – SCP2R-CV- Designed to work with conventional fire panels- Easily reset using the reset key provided- Complete with surface mounting box- Material: ABS fire retardant plastic- IP rating: IP40 (indoor only)- Voltage: 9-30VDC
-
Apollo Heat Detector Cs Static Series for XP95
£36.58 Incl. VATThe XP95 Heat Detector monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature. The XP95 range features two heat detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55C. The high temperature detector, classified as a CS device, will report an alarm at 90C.- standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55C. The high temperature detector- classified as a CS device- will report an alarm at 90C. Suitable for commercial- industrial- financial- government- IT/telecoms and healthcare applications.- CS classified- Reports an alarm at 90C- Ideal in environments that are dirty or smoky under normal conditions
-
Apollo Xpert Universal Address Card (Pack Of 25)
£7.31 Incl. VATA universal XPERT card which allows you to use the same card on both XPERT 7 and XPERT 8 bases.- Allows installation in all base types, meaning you only need to carry this one type of card alleviating the need for multiple cards when using Apollo products.- Flexibility to create any address; includes 128th pip for CoreProtocol systems- An additional lead-in on the address pips allows for a higher tolerance- Simplifies and speeds up installation and commissioning- Simplifies and speeds up installation and commissioning- Address remains the same, no matter how often the detectors are replaced