Schneider RCBO iC60H2 Double Pole Curve C Type A 10A 30mA

Schneider RCBO iC60H2 Double Pole Curve C Type A 10A 30mA

£246.44 Incl. VAT

A9D11210 iC60H2 10A DP RCBO C Curve 30mA Type A 240V. The 2-pole iC60H2 RCBOs self-contained residual current device carries out b complete protection of final circuits: protection against short-circuits and cable overloads, protection of persons against electric shock by direct contact (30 mA sensitivities). iC60H2 RCBO switches neutral, together with phase. It is therefore suitable for all circuits, whatever the earthing system (except for TN-C). · · · This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). · · It is a 2P circuit breaker with 2 protected poles, In rated current of 10A and C tripping curve. · · The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. · · The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. · · Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. · · Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. · · Its fast closing mechanism independent of manual operation improves its service life. · · This product is compliant with AS/NZS 61009.1 and IEC 61009-1 standard. · · It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 240VAC.

8 available – delivery in 1–2 days

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
SKU: A9D11210 Categories: , , Brand: Part Number: 2500866921

Description

Technical Specifications  Technical Specifications Earth leakage circuit breaker/RCBO Mounting method DIN rail Rated current 10 A Tripping characteristic (type/curve) C Rated voltage 240 V Recess depth 45 mm Width in number of modular spacings 2 Pollution degree 3 Over voltage category 4 Number of protected poles 2 Rated impulse-withstand voltage (Uimp) 4 kV Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA Rated insulation voltage Ui 400 V Rated fault current 0.03 A Surge current capacity 0.25 kA Number of poles (total) 2 Current limiting class 3 Connectable conductor cross section solid-core 1 – 25 mm² Connectable conductor cross section multi-wired 1 – 16 mm² Ambient temperature during operating -15 – 60 °C With interlocking device No Suitable for flush-mounted installation No Anti-nuisance tripping version No Concurrently switching N-neutral Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2199805