Schneider RCBO iC60H2 Double Pole Curve C Type A 32A 30mA
£246.44 Incl. VAT
A9D11232 iC60H2 32A DP RCBO C Curve 30mA Type A 240V. The 2-pole iC60H2 RCBOs self-contained residual current device carries out b complete protection of final circuits: protection against short-circuits and cable overloads, protection of persons against electric shock by direct contact (30 mA sensitivities). iC60H2 RCBO switches neutral, together with phase. It is therefore suitable for all circuits, whatever the earthing system (except for TN-C). · · · This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). · · It is a 2P circuit breaker with 2 protected poles, In rated current of 32A and C tripping curve. · · The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. · · The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. · · Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. · · Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. · · Its fast closing mechanism independent of manual operation improves its service life. · · This product is compliant with AS/NZS 61009.1 and IEC 61009-1 standard. · · It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. · · The Ue operational voltage is 240VAC.
Out of stock
Description
Technical Specifications Technical Specifications Earth leakage circuit breaker/RCBO Mounting method DIN rail Tripping characteristic (type/curve) C Rated insulation voltage Ui 400 V Rated fault current 0.03 A Width in number of modular spacings 2 Current limiting class 3 Number of protected poles 2 Rated impulse-withstand voltage (Uimp) 4 kV Rated current 32 A Recess depth 45 mm Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA Over voltage category 4 Pollution degree 3 Surge current capacity 0.25 kA Number of poles (total) 2 Rated voltage 240 V Connectable conductor cross section solid-core 1 – 25 mm² Connectable conductor cross section multi-wired 1 – 16 mm² Ambient temperature during operating -15 – 60 °C With interlocking device No Suitable for flush-mounted installation No Anti-nuisance tripping version No Concurrently switching N-neutral Yes · Technical Data Sheet – Click to Download · Manual: https://asset.eezybridge.com/ad7e7626-8f4a-4edb-b78d-9ca040e321dd/2199805